distal biceps repair system
Enabling anatomic reattachment of the distal biceps tendon
Anatomic by Design.
Purpose-Built for Repair.
The supinX™ Distal Biceps Repair System is designed to enable anatomic reattachment of the distal biceps tendon through a single-incision anterior approach using a minimally invasive, bone-preserving technique and proprietary automation technologies.
THE A-LIST
Anatomic Restoration
Facilitates tendon reattachment to the native distal biceps footprint through either a single-head or double-head repair technique, supporting the distal biceps’ natural biomechanics and function.
Anterior Single-Incision
Employs the standard and widely accepted single-incision anterior approach supporting a consistent and reproducible technique for accessing the radial tuberosity and reattachment of the biceps tendon.
Automation
The patented Golden Retriever™ guide enables precise targeting and streamlined suture management. The proprietary Button Threader automatically loads the button onto the suture strands, simplifying tendon fixation.
Atraumatic
Utilizes a minimally invasive, 2mm bone-preserving tunnel to reattach the biceps tendon. The low-profile cortical button sits on the anterior aspect of the radial tuberosity, clear of neurovascular structures.
Supports Natural Motion
By reattaching the biceps tendon to the native footprint, the supinX™ system helps recreate the distal biceps’ natural biomechanics and function, including forearm supination strength and rotational range of motion.
Purpose-Built
Instrumentation.
An optimized set of instruments designed to simplify the procedure and support a consistent, reproducible technique.
Golden Retriever™
Designed to facilitate atraumatic passage and retrieval of the suture limbs through the 2mm bone tunnel, reducing soft tissue disruption and supporting a streamlined procedure.
Button Threader
Automates controlled delivery of the tendon suture limbs to the distal biceps button through the 2mm bone tunnel, helping to streamline button deployment and alleviate manual button to suture threading time.
Instrument Set Includes
| 1 | DBR-DG-20 | Drill Guide |
| 2 | DBR-DG-LR | Drill Guide Locking Rod, Distal Biceps Repair |
| 3 | DBR-SPG | Suture Passing Guide |
| 4 | STX-VCE | STABLYX, Volar Capsule Elevator/Shoehorn |
| 5 | DRLL-20124 | Distal Biceps Drill, 2.0mm x 124mm |
| 6 | INST-MHR-STD | Instrument, Mini-Hohmann Retractor, Standard |
| 7 | KNT-PSH | Knot Pusher |
Sterile Implant Kit Includes
| DBR-BLU-01 or DBR-BLK-01 | ||
| 1a | — | #2 Suture Loop, ST Needle |
| 1b | — | 2-0 Suture Passing Needle Assembly |
| 1c | — | Button Threader Assembly |
| 1d | — | Circular Button, #2 Suture |